    "tag": [
        "compiled"
    ],
    "id": "ocds-h6vhtk-038b84-2022-12-19T08:38:35Z",
    "date": "2022-12-19T08:38:35Z",
    "ocid": "ocds-h6vhtk-038b84",
    "initiationType": "tender",
    "tender": {
        "id": "2022/1973/CIMS/HC",
        "legalBasis": {
            "id": "32014L0024",
            "scheme": "CELEX"
        },
        "title": "Chemical Ionisation Mass Spectrometer",
        "status": "complete",
        "classification": {
            "scheme": "CPV",
            "id": "38433100",
            "description": "Mass spectrometer"
        },
        "mainProcurementCategory": "goods",
        "description": "The University intends to acquire a Chemical Ionisation (CI)-Time of Flight (ToF) is an ultrasensitive mass spectrometer The Centre for Atmospheric Sciences (CAS) at the University of Manchester is interested in a wide range of environmental science challenges, which involve under-standing the transfer of molecules between gas, liquid and solid phases.",
        "lots": [
            {
                "id": "1",
                "description": "The University intends to acquire a Chemical Ionisation (CI)-Time of Flight (ToF) is an ultrasensitive mass spectrometer The Centre for Atmospheric Sciences (CAS) at the University of Manchester is interested in a wide range of environmental science challenges, which involve under-standing the transfer of molecules between gas, liquid and solid phases.",
                "hasOptions": false,
                "awardCriteria": {
                    "criteria": [
                        {
                            "name": "Technical VFM",
                            "type": "cost",
                            "description": "100"
                        }
                    ]
                },
                "status": "cancelled"
            }
        ],
        "items": [
            {
                "id": "1",
                "deliveryAddresses": [
                    {
                        "region": "UKD3"
                    },
                    {
                        "region": "UKD3"
                    }
                ],
                "deliveryLocation": {
                    "description": "The University of Manchester"
                },
                "relatedLot": "1"
            }
        ],
        "procurementMethod": "limited",
        "procurementMethodDetails": "Award procedure without prior publication of a call for competition",
        "coveredBy": [
            "GPA"
        ],
        "procurementMethodRationaleClassifications": [
            {
                "scheme": "TED_PT_AWARD_CONTRACT_WITHOUT_CALL",
                "id": "D_TECHNICAL",
                "description": "The works, supplies or services can be provided only by a particular economic operator due to absence of competition for technical reasons"
            }
        ],
        "procurementMethodRationale": "A CI-TOF is an ultra-sensitive mass spectrometer for the online characterization of trace gases and aerosols in complex mixtures. This instrument will provide a high-resolution time of-flight mass spectrometer with bipolar power supply for positive or negative ion detection with interchangeable reactors for a full range of measurement options over an extensive volatility range. Interchange of these chemical ionization ion-molecule reactors will be possible while maintaining the operating pressure of the interface and TOF chambers . This instrument will provide simultaneous switching between multiple (three or less) reagent ions of the same polarity with the PTR and AIM reactors and have the capability to connect reactors to inlets that allows for particulate and gas phase compositions in real time (VIA inlet (PTR reactor), FIGAERO Inlet (AIM reactor)). This instrument will also provide an Extractive Electrospray (EESI) inlet that allows for detection of particle phase components without thermal vaporization. Key performance specifications are: Sensitivity with PTR Reactor (xylene): 30001 cps/ppb at specified mass resolving power of 10,000. Sensitivity with Aim Reactor (levoglucosan): 30001 cps/ppb at specified mass resolving power. Limits of detection PTR Reactor (3 sigma LOD, xylene): 1E4 in 1 second Time response."
    },
    "awards": [
        {
            "id": "034668-2022-2022/1973/CIMS/HC-1",
            "relatedLots": [
                "1"
            ],
            "title": "Chemical Ionisation Mass Spectrometer",
            "status": "active",
            "suppliers": [
                {
                    "id": "GB-FTS-70278",
                    "name": "Aerodyne Research Inc."
                }
            ]
        },
        {
            "id": "035771-2022-2022/1973/CIMS/HC-1",
            "relatedLots": [
                "1"
            ],
            "title": "Chemical Ionisation Mass Spectrometer",
            "status": "active",
            "suppliers": [
                {
                    "id": "GB-FTS-70278",
                    "name": "Aerodyne Research Inc."
                }
            ]
        }
    ],
    "parties": [
        {
            "id": "GB-UKPRN-10007798",
            "name": "UNIVERSITY OF MANCHESTER",
            "identifier": {
                "legalName": "UNIVERSITY OF MANCHESTER",
                "id": "10007798",
                "scheme": "GB-UKPRN"
            },
            "address": {
                "streetAddress": "Room G010,John Owens Building, Oxford Road",
                "locality": "MANCHESTER",
                "region": "UKD33",
                "postalCode": "M139PL",
                "countryName": "United Kingdom"
            },
            "contactPoint": {
                "name": "Paul Carter",
                "email": "paul.carter-2@manchester.ac.uk",
                "telephone": "+44 1612752207"
            },
            "roles": [
                "buyer"
            ],
            "details": {
                "url": "http://www.procurement.manchester.ac.uk/",
                "classifications": [
                    {
                        "scheme": "TED_CA_TYPE",
                        "id": "BODY_PUBLIC",
                        "description": "Body governed by public law"
                    },
                    {
                        "scheme": "COFOG",
                        "id": "09",
                        "description": "Education"
                    }
                ]
            }
        },
        {
            "id": "GB-FTS-70278",
            "name": "Aerodyne Research Inc.",
            "identifier": {
                "legalName": "Aerodyne Research Inc.",
                "noIdentifierRationale": "notOnAnyRegister"
            },
            "address": {
                "locality": "Billerica",
                "region": "US",
                "countryName": "United States"
            },
            "roles": [
                "supplier"
            ],
            "details": {
                "scale": "large"
            }
        },
        {
            "id": "GB-FTS-1152",
            "name": "The High Court of Justice of England",
            "identifier": {
                "legalName": "The High Court of Justice of England"
            },
            "address": {
                "streetAddress": "Strand",
                "locality": "London",
                "postalCode": "WC2A 2LL",
                "countryName": "United Kingdom"
            },
            "roles": [
                "reviewBody"
            ]
        },
        {
            "id": "GB-FTS-9727",
            "name": "The University of Manchester",
            "identifier": {
                "legalName": "The University of Manchester"
            },
            "address": {
                "streetAddress": "Oxford Road",
                "locality": "Manchester",
                "postalCode": "M13 9PL",
                "countryName": "United Kingdom"
            },
            "roles": [
                "reviewContactPoint"
            ]
        }
    ],
    "buyer": {
        "id": "GB-UKPRN-10007798",
        "name": "UNIVERSITY OF MANCHESTER"
    },
    "contracts": [
        {
            "id": "034668-2022-2022/1973/CIMS/HC-1",
            "awardID": "034668-2022-2022/1973/CIMS/HC-1",
            "title": "Chemical Ionisation Mass Spectrometer",
            "status": "active",
            "value": {
                "amount": 762430,
                "currency": "USD"
            },
            "dateSigned": "2022-12-06T00:00:00Z"
        },
        {
            "id": "035771-2022-2022/1973/CIMS/HC-1",
            "awardID": "035771-2022-2022/1973/CIMS/HC-1",
            "title": "Chemical Ionisation Mass Spectrometer",
            "status": "active",
            "value": {
                "amount": 762430,
                "currency": "USD"
            },
            "dateSigned": "2022-12-19T00:00:00Z"
        }
    ],
    "language": "en",
    "bids": {
        "statistics": [
            {
                "id": "1",
                "measure": "bids",
                "relatedLot": "1",
                "value": 1
            }
        ]
    }
}