    "tag": [
        "compiled"
    ],
    "id": "ocds-h6vhtk-047d59-2024-07-15T11:51:38+01:00",
    "date": "2024-07-15T11:51:38+01:00",
    "ocid": "ocds-h6vhtk-047d59",
    "initiationType": "tender",
    "tender": {
        "id": "ocds-h6vhtk-047d59",
        "legalBasis": {
            "id": "32014L0024",
            "scheme": "CELEX"
        },
        "title": "sSNOM Upgrade for University of Manchester",
        "status": "complete",
        "classification": {
            "scheme": "CPV",
            "id": "38000000",
            "description": "Laboratory, optical and precision equipments (excl. glasses)"
        },
        "mainProcurementCategory": "goods",
        "description": "Upgrade enabling time-resolved pump-probe spectroscopy for cryogenic THz-TDS near-field measurements. The pump laser must be synchronized with the existing THz-TDS spectroscopy and cryogenic near-field systems. The upgrade includes a laser amplifier unit with free-space coupled optical output at 780nm, 100MHz rep rate, pulse energy >1.3nJ, >140mW output power, and customized fiber patch cord for temporal overlap of pump-probe pulses. Additionally, a transmission module enables static pump-probe measurements in transmission, where the sample is pumped via a diffraction-limited beam from the bottom and probed by amplitude- & phase-resolved near-field measurements (pseudo-heterodyne detection) from the top.",
        "lots": [
            {
                "id": "1",
                "description": "Upgrade for cryo-neaSCOPE+xs s-SNOM system can only be provided by the base system's manufacturer - attocube systems AG. Needs and requirements include: 1. Ultra-fast spectroscopy software module for THz-TDS * Enables pump-probe spectroscopy for THz-TDS in neaSCAN * Provides software control of all delays and components for ready-to-use results * Allows acquisition of time-resolved spectra with down to 40 fs temporal resolution 2. Synchronized Transmission-Mode Detection Module * Enables bottom-side sample illumination in transmission-mode with broadband parabolic mirror (NA=0.44) * Enables simultaneous detection of optical near-field amplitude & phase * Motorized parabolic mirror for beam-alignment * Stationary focal point with respect to AFM-tip * Variable illumination spot size (ca. 2mm - 100mm) * Suitable for plane-wave illumination * Exchangeable beam-splitter mount * Supports stationary focal point with respect to sample position (bottom-side illumination synchronized with sample scanner) * Support AFM scan-speed: up to 20 mm/s @ highest spatial resolution 3. Software Development Kit for neaSCAN 4. THz Pump-Probe operation * additional delay line & synchronized software control for pump probe * amplifier unit with free-space coupled optical output at 780nm with amplifier unit mounted on optical table next to neaSNOM microscope * 100MHz rep rate, pulse energy >1.3nJ, >140mW output power * Customized fiber patch cord for temporal overlap of pump-probe pulses",
                "awardCriteria": {
                    "criteria": [
                        {
                            "name": "Technical",
                            "type": "cost",
                            "description": "90%"
                        },
                        {
                            "name": "Commercial",
                            "type": "cost",
                            "description": "10%"
                        }
                    ]
                },
                "hasOptions": false
            }
        ],
        "items": [
            {
                "id": "1",
                "deliveryAddresses": [
                    {
                        "region": "UK"
                    }
                ],
                "deliveryLocation": {
                    "description": "Photon Science Institute, University of Manchester, M13 9PL"
                },
                "relatedLot": "1"
            }
        ],
        "procurementMethod": "limited",
        "procurementMethodDetails": "Award procedure without prior publication of a call for competition",
        "coveredBy": [
            "GPA"
        ],
        "procurementMethodRationaleClassifications": [
            {
                "scheme": "TED_PT_AWARD_CONTRACT_WITHOUT_CALL",
                "id": "D_OUTSIDE_SCOPE",
                "description": "The procurement falls outside the scope of application of the directive"
            }
        ],
        "procurementMethodRationale": "Attocube systems AG is the only company worldwide, who manufactures a scattering-type near-field optical microscope (our pre-upgrade system) that enables simultaneous background-free imaging and spectroscopy on nanometre length scales in the visible-IR-THz range. Their exclusive design works with the following patents: * Patented parabolic mirror design for focusing and collection of light * Patented dual-port design to allow two beams of light to be focused on the atomic force microscope (AFM) tip for nanoscale imaging and spectroscopy * Patented signal processing for optical background suppression * Patented pseudo-heterodyne detection (PsHet) technology for background suppression * Patented interferometric design (nano-FTIR) for background-free optical detection technology and simultaneous detection of optical amplitude and phase and hyperspectral imaging * Patented high speed holography for multispectral imaging * Patented phase shifting detection to extract relative phase These patents and the exclusive design have enabled the neaSCOPE system to conduct amplitude and phase-resolved vector field, reflection, and absorption mapping with nanoscale spatial resolution. It is currently the only solution provider on the market that enables dual-port s-SNOM operation combined with a high NA parabolic mirror, which is essential for low SNR THz TDS and pump-probe measurements. In particular, attocube systems AG is the only company who can upgrade the existing cryogenic s-SNOM system (cryo-neaSCOPE) based at University of Manchester to perform nanoscale THz-TDS and pump-probe imaging and spectroscopy at low temperature. Therefore, the same manufacture of the pre-upgraded s-SNOM system is required to ensure: * All upgrade subsystems must be compatible with the existing microscope controls (both in hardware and software), while still being amplitude- & phase-resolved and background-free. * Pump laser must be electronically synchronized with the existing cryogenic THz-TDS spectroscopy system * Excitation wavelength must be compatible with optical windows in the cold shroud of the existing cryo-neaSCOPE system"
    },
    "awards": [
        {
            "id": "021633-2024-1",
            "relatedLots": [
                "1"
            ],
            "status": "active",
            "hasSubcontracting": true,
            "suppliers": [
                {
                    "id": "GB-FTS-118469",
                    "name": "attocube system AG"
                }
            ]
        }
    ],
    "parties": [
        {
            "id": "GB-FTS-155",
            "name": "National Physical Laboratory",
            "identifier": {
                "legalName": "National Physical Laboratory"
            },
            "address": {
                "streetAddress": "Hampton Road",
                "locality": "Teddington",
                "region": "UK",
                "postalCode": "TW11 0LW",
                "countryName": "United Kingdom"
            },
            "contactPoint": {
                "email": "nina.heath@npl.co.uk"
            },
            "roles": [
                "buyer"
            ],
            "details": {
                "url": "http://www.npl.co.uk",
                "classifications": [
                    {
                        "scheme": "TED_CA_TYPE",
                        "id": "BODY_PUBLIC",
                        "description": "Body governed by public law"
                    },
                    {
                        "scheme": "COFOG",
                        "description": "Research"
                    }
                ]
            }
        },
        {
            "id": "GB-FTS-118469",
            "name": "attocube system AG",
            "identifier": {
                "legalName": "attocube system AG"
            },
            "address": {
                "streetAddress": "Eglfinger Weg 2,",
                "locality": "Haar",
                "region": "DE",
                "postalCode": "85540",
                "countryName": "Germany"
            },
            "roles": [
                "supplier"
            ],
            "details": {
                "scale": "sme"
            }
        },
        {
            "id": "GB-FTS-156",
            "name": "NPL Management Ltd",
            "identifier": {
                "legalName": "NPL Management Ltd"
            },
            "address": {
                "streetAddress": "Hampton Road",
                "locality": "Teddington",
                "postalCode": "TW11 0LW",
                "countryName": "United Kingdom"
            },
            "roles": [
                "reviewBody",
                "mediationBody"
            ]
        }
    ],
    "buyer": {
        "id": "GB-FTS-155",
        "name": "National Physical Laboratory"
    },
    "contracts": [
        {
            "id": "021633-2024-1",
            "awardID": "021633-2024-1",
            "status": "active",
            "value": {
                "amount": 262370,
                "currency": "EUR"
            },
            "dateSigned": "2024-07-15T00:00:00+01:00"
        }
    ],
    "language": "en"
}