    "tag": [
        "compiled"
    ],
    "id": "ocds-h6vhtk-04a7e9-2024-10-30T13:55:49Z",
    "date": "2024-10-30T13:55:49Z",
    "ocid": "ocds-h6vhtk-04a7e9",
    "initiationType": "tender",
    "tender": {
        "id": "DLSPAG0160",
        "legalBasis": {
            "id": "32014L0024",
            "scheme": "CELEX"
        },
        "title": "DLSPAG0160 - Supply of Vacuum Gauges & Control Units for Diamond-II",
        "status": "complete",
        "classification": {
            "scheme": "CPV",
            "id": "38423100",
            "description": "Pressure gauges"
        },
        "mainProcurementCategory": "goods",
        "description": "Located on the Harwell Science and Innovation Campus in Oxfordshire, Diamond Light Source (DLS) is a leading-edge facility for science, engineering and innovation. Diamond allows researchers from academia and industry to investigate the structure and behaviour of the world around us at the atomic and molecular level. To continue delivering the world-changing science that Diamond enables, the facility is being upgraded to Diamond-II, a co-ordinated programme of development that combines a major machine upgrade with new instruments and complementary improvements to optics, detectors, sample environment and delivery capabilities, and computing, as well as integrated and correlative methods. This will be transformative in speed and spatial resolution and will offer users streamlined access to enhanced instruments for life and physical sciences. Currently Diamond has a legacy installation of around 1000 Gauge sets and 500 Gauge controllers from MKS. In the Diamond-II accelerator upgrade we plan on using the legacy controllers and purchase new gauges and a few additional new controllers. Approximately numbers of new kit for Diamond-II is 370 gauge sets and 55 Gauge controllers. 1. The MKS gauge controllers which are currently integrated in the racks and control systems for Diamond are planned to be used again on Diamond II accelerators. 2. The MKS gauge controllers are not compatible with any other makers gauges in the market. 3. There are no gauge controllers in the market which are compatible with the MKS gauges. 4. It is not currently possible to buy gauges and controllers from an alternative supplier to fit with what we already have. There are no gauge controllers in the market that have a fast response trigger that can be used without fast valve controller system. The requirement is for equipment that is compatible with the existing installation: * Pirani gauges * Inverted Magnetron vacuum gauges * Vacuum gauge control units",
        "lots": [
            {
                "id": "1",
                "description": "Located on the Harwell Science and Innovation Campus in Oxfordshire, Diamond Light Source (DLS) is a leading-edge facility for science, engineering and innovation. Diamond allows researchers from academia and industry to investigate the structure and behaviour of the world around us at the atomic and molecular level. To continue delivering the world-changing science that Diamond enables, the facility is being upgraded to Diamond-II, a co-ordinated programme of development that combines a major machine upgrade with new instruments and complementary improvements to optics, detectors, sample environment and delivery capabilities, and computing, as well as integrated and correlative methods. This will be transformative in speed and spatial resolution and will offer users streamlined access to enhanced instruments for life and physical sciences. Currently Diamond has a legacy installation of around 1000 Gauge sets and 500 Gauge controllers from MKS. In the Diamond-II accelerator upgrade we plan on using the legacy controllers and purchase new gauges and a few additional new controllers. Approximately numbers of new kit for Diamond-II is 370 gauge sets and 55 Gauge controllers. 1. The MKS gauge controllers which are currently integrated in the racks and control systems for Diamond are planned to be used again on Diamond II accelerators. 2. The MKS gauge controllers are not compatible with any other makers gauges in the market. 3. There are no gauge controllers in the market which are compatible with the MKS gauges. 4. It is not currently possible to buy gauges and controllers from an alternative supplier to fit with what we already have. There are no gauge controllers in the market that have a fast response trigger that can be used without fast valve controller system. The requirement is for equipment that is compatible with the existing installation: * Pirani gauges * Inverted Magnetron vacuum gauges * Vacuum gauge control units.",
                "hasOptions": false,
                "awardCriteria": {
                    "criteria": [
                        {
                            "type": "price"
                        }
                    ]
                },
                "status": "cancelled"
            }
        ],
        "items": [
            {
                "id": "1",
                "deliveryAddresses": [
                    {
                        "region": "UKJ14"
                    },
                    {
                        "region": "UKJ14"
                    }
                ],
                "relatedLot": "1"
            }
        ],
        "procurementMethod": "limited",
        "procurementMethodDetails": "Award procedure without prior publication of a call for competition",
        "coveredBy": [
            "GPA"
        ],
        "procurementMethodRationaleClassifications": [
            {
                "scheme": "TED_PT_AWARD_CONTRACT_WITHOUT_CALL",
                "id": "D_OUTSIDE_SCOPE",
                "description": "The procurement falls outside the scope of application of the directive"
            }
        ],
        "procurementMethodRationale": "Currently Diamond has a legacy installation of around 1000 Gauge sets and 500 Gauge controllers from MKS. In the Diamond-II accelerator upgrade we plan on using the legacy controllers and purchase new gauges and a few additional new controllers. Approximately numbers of new kit for Diamond-II is 370 gauge sets and 55 Gauge controllers. 1. The MKS gauge controllers which are currently integrated in the racks and control systems for Diamond are planned to be used again on Diamond II accelerators. 2. The MKS gauge controllers are not compatible with any other makers gauges in the market. 3. There are no gauge controllers in the market which are compatible with the MKS gauges. 4. It is not currently possible to buy gauges and controllers from an alternative supplier to fit with what we already have. There are no gauge controllers in the market that have a fast response trigger that can be used without fast valve controller system. The requirement is for equipment that is compatible with the existing installation: * Pirani gauges * Inverted Magnetron vacuum gauges * Vacuum gauge control units"
    },
    "awards": [
        {
            "id": "032736-2024-1",
            "relatedLots": [
                "1"
            ],
            "status": "active",
            "suppliers": [
                {
                    "id": "GB-COH-06391618",
                    "name": "MKS Instruments UK Limited"
                }
            ]
        },
        {
            "id": "035175-2024-DLSPAG0160-1",
            "relatedLots": [
                "1"
            ],
            "title": "Supply of Vacuum Gauges & Control Units for Diamond-II",
            "status": "active",
            "suppliers": [
                {
                    "id": "GB-COH-06391618",
                    "name": "MKS Instruments UK Ltd"
                }
            ]
        }
    ],
    "parties": [
        {
            "id": "GB-COH-4375679",
            "name": "Diamond Light Source Ltd",
            "identifier": {
                "legalName": "Diamond Light Source Ltd",
                "id": "4375679",
                "scheme": "GB-COH"
            },
            "address": {
                "streetAddress": "Harwell Science and Innovation Campus",
                "locality": "Didcot",
                "region": "UKJ14",
                "postalCode": "OX11 0DE",
                "countryName": "United Kingdom"
            },
            "contactPoint": {
                "name": "Debbie Pryor",
                "telephone": "+44 1235567575",
                "email": "procurement@diamond.ac.uk"
            },
            "roles": [
                "buyer"
            ],
            "details": {
                "url": "https://www.diamond.ac.uk",
                "classifications": [
                    {
                        "scheme": "TED_CA_TYPE",
                        "id": "BODY_PUBLIC",
                        "description": "Body governed by public law"
                    },
                    {
                        "scheme": "COFOG",
                        "description": "Scientific Research"
                    }
                ]
            }
        },
        {
            "id": "GB-COH-06391618",
            "name": "MKS Instruments UK Ltd",
            "identifier": {
                "legalName": "MKS Instruments UK Ltd",
                "id": "06391618",
                "scheme": "GB-COH"
            },
            "address": {
                "locality": "Crewe, Cheshire",
                "region": "UKD6",
                "postalCode": "CW1 6AE",
                "countryName": "United Kingdom",
                "streetAddress": "2 Cowley Way, Weston Road,"
            },
            "roles": [
                "supplier"
            ],
            "details": {
                "scale": "large"
            }
        },
        {
            "id": "GB-FTS-89839",
            "name": "Diamond Light Source",
            "identifier": {
                "legalName": "Diamond Light Source"
            },
            "address": {
                "streetAddress": "Harwell Science and Innovation Campus",
                "locality": "Didcot",
                "postalCode": "OX11 0ED",
                "countryName": "United Kingdom"
            },
            "roles": [
                "reviewBody"
            ]
        },
        {
            "id": "GB-FTS-85339",
            "name": "Diamond Light Source",
            "identifier": {
                "legalName": "Diamond Light Source"
            },
            "address": {
                "locality": "Didcot",
                "postalCode": "OX11 0DE",
                "countryName": "United Kingdom"
            },
            "roles": [
                "reviewBody"
            ]
        }
    ],
    "buyer": {
        "id": "GB-COH-4375679",
        "name": "Diamond Light Source Ltd"
    },
    "contracts": [
        {
            "id": "032736-2024-1",
            "awardID": "032736-2024-1",
            "status": "active",
            "value": {
                "amount": 767195,
                "currency": "GBP"
            },
            "dateSigned": "2024-10-11T00:00:00+01:00"
        },
        {
            "id": "035175-2024-DLSPAG0160-1",
            "awardID": "035175-2024-DLSPAG0160-1",
            "title": "Supply of Vacuum Gauges & Control Units for Diamond-II",
            "status": "active",
            "value": {
                "amount": 0.01,
                "currency": "GBP"
            },
            "dateSigned": "2024-10-23T00:00:00+01:00"
        }
    ],
    "language": "en",
    "bids": {
        "statistics": [
            {
                "id": "1",
                "measure": "bids",
                "relatedLot": "1",
                "value": 1
            }
        ]
    }
}