    "tag": [
        "compiled"
    ],
    "id": "ocds-kuma6s-158062-2025-11-12T16:14:45Z",
    "date": "2025-11-12T16:14:45Z",
    "ocid": "ocds-kuma6s-158062",
    "initiationType": "tender",
    "parties": [
        {
            "id": "org-5",
            "name": "Newport Norse",
            "address": {
                "streetAddress": "1st Floor Caradog House, Cleppa Park,",
                "locality": "Newport",
                "postalCode": "NP10 8UG"
            },
            "contactPoint": {
                "name": "Sarah Jones",
                "telephone": "+44 1633240456"
            },
            "roles": [
                "buyer"
            ]
        }
    ],
    "buyer": {
        "name": "Newport Norse",
        "id": "org-5"
    },
    "tender": {
        "id": "ocds-kuma6s-158062-tender-158062",
        "title": "Installation of Heat Pumps at Blaen y pant Care Home, Newport NP20 5PX",
        "description": "Newport City council is looking to appoint a suitably qualified and experienced mechanical, electrical, civils and controls contractor to undertake a heat pump supply and installation and integration with the existing space heating and DHW circuits within Blaen-y-Pant Care Home, located in Newport, South Wales.NOTE: To register your interest in this notice and obtain any additional information please visit the Sell2Wales Web Site at https://www.sell2wales.gov.wales/Search/Search_Switch.aspx?ID=158062.The buyer has indicated that it will accept electronic responses to this notice via the Postbox facility. A user guide is available at https://www.sell2wales.gov.wales/sitehelp/help_guides.aspx.Suppliers are advised to allow adequate time for uploading documents and to dispatch the electronic response well in advance of the closing time to avoid any last minute problems. (WA Ref:158062)",
        "procurementMethod": "open",
        "mainProcurementCategory": "works",
        "submissionMethodDetails": "http://www.sell2wales.gov.wales/",
        "tenderPeriod": {
            "endDate": "2025-12-03T12:00:00Z"
        },
        "eligibilityCriteria": "Contractor to be registered with Safe Contractor and hold full, enhanced DBS checks. The Contractor is required to execute the works to provide a safe, cost-effective, high-quality installation compliant with all prevailing good industry practice, regulations and statutory requirements and in accordance with all tender drawings and specifications. The design, installation and operation of the heat pump shall be fully compliant with EN 378 (all parts) where applicable.",
        "awardPeriod": {
            "endDate": "2025-12-12T00:00:00Z"
        },
        "documents": [
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-1",
                "title": "REP01-P01 Noise Impact Assessment - Blaen Y Pant Care Home ASHP",
                "datePublished": "2025-11-12T16:14:45Z",
                "dateModified": "2025-11-12T16:14:45Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-2",
                "title": "Enquin Report",
                "datePublished": "2025-11-12T16:14:45Z",
                "dateModified": "2025-11-12T16:14:45Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-3",
                "title": "CC2945 Issue Sheet 31.10.2025",
                "datePublished": "2025-11-12T16:14:45Z",
                "dateModified": "2025-11-12T16:14:45Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-4",
                "title": "CC2945-CAM-XX-XX-DR-C-0500-S3-P01_ASHP Slab Drainage Layout",
                "datePublished": "2025-11-12T16:14:45Z",
                "dateModified": "2025-11-12T16:14:45Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-5",
                "title": "CC2945-CAM-XX-XX-D-S-2100-P02-ENERGY CENTRE FOUNDATION GENERAL ARRANGEMENT & DETAILS",
                "datePublished": "2025-11-12T16:14:45Z",
                "dateModified": "2025-11-12T16:14:45Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-6",
                "title": "ADP BLAEN Y PANT CARE HOME",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-7",
                "title": "ADP-BLAEN Y PANT",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/octet-stream"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-8",
                "title": "2619-SEL-DD-001-V04 Drawing and Document Register",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-9",
                "title": "2619-SEL-ZZ-XX-DR-M-1001-S3 - Blaen-Y-Pant Care Home 2D Layout",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/octet-stream"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-10",
                "title": "2619-SEL-ZZ-XX-DRA-Y-001-S3-P01 Design Risk Register",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-11",
                "title": "2619-SEL-ZZ-XX-SH-ME-0001-S3-P02 Equipment Schedule",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-12",
                "title": "2619-SEL-ZZ-XX-SH-ME-0002-S3-P03 Load Schedule",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-13",
                "title": "2619-SEL-ZZ-XX-SH-Y-0001-S3-P01 MQTT Topic Schedule",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-14",
                "title": "2619-SEL-ZZ-XX-SH-Y-0002-S3-P01 Packaged Plant Room IO Schedule",
                "datePublished": "2025-11-12T16:14:46Z",
                "dateModified": "2025-11-12T16:14:46Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-15",
                "title": "2619-SEL-ZZ-XX-SP-Z-0001-S3-P02 Equipment Specification",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-16",
                "title": "2619-SEL-ZZ-XX-SP-Z-0002-S3-P02 Mechanical and Electrical Specification",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-17",
                "title": "2619-SEL-ZZ-XX-SW-Z-0001-S3-P03 Blaen-Y-Pant Care Home Scope of Works",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-18",
                "title": "2619-SEL-ZZ-XX-DR-E-6001-S3-P03 Single Line Diagram",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-19",
                "title": "2619-SEL-ZZ-XX-DR-E-6002-S3-P01 Communications Control Schematic",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-20",
                "title": "2619-SEL-ZZ-XX-DR-M-5001-S3 P02 - Trench Route Overview & Pinch Points",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-21",
                "title": "2619-SEL-ZZ-XX-DR-M-5002-S3 P01 - Trench details",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-22",
                "title": "2619-SEL-ZZ-XX-DR-M-5003-S3 P01 - Plant Room Entry and Wall Penetration Details",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-23",
                "title": "2619-SEL-ZZ-XX-DR-M-7000-S3-P01 Master Symbol List",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-24",
                "title": "2619-SEL-ZZ-XX-DR-Y-7001-S3-P01 Existing System P&ID",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-25",
                "title": "2619-SEL-ZZ-XX-DR-Y-7002-S3-P02 Proposed Energy Centre P&ID",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-26",
                "title": "2619-SEL-ZZ-XX-DR-Y-7003-S3-P01 Connection to Existing System P&ID",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-27",
                "title": "2619-SEL-ZZ-XX-GA-M-1001-S3 P01 - Existing Plant Room Layout",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-28",
                "title": "2619-SEL-ZZ-XX-GA-M-1002-S3 P01 - Proposed Plant Room Layout - Plan View",
                "datePublished": "2025-11-12T16:14:47Z",
                "dateModified": "2025-11-12T16:14:47Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-29",
                "title": "2619-SEL-ZZ-XX-GA-M-1003-S3 P01 - Proposed Plant Room Layout - Sections D and C",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-30",
                "title": "2619-SEL-ZZ-XX-GA-M-1004-S3 P01 - Proposed Plant Room Layout - Sections E and F",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-31",
                "title": "2619-SEL-ZZ-XX-GA-M-1005-S3 P01 - Proposed External Energy Centre - Plan View",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-32",
                "title": "2619-SEL-ZZ-XX-GA-M-1006-S3 P02 - Proposed External Energy Centre - Additional View",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-33",
                "title": "2619-SEL-ZZ-XX-GA-M-1007-S3 P02 - Proposed Concrete Base Loading Layout",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-34",
                "title": "2619-SEL-ZZ-XX-GA-M-1008-S3 P02 - Proposed Prefabricated Plantroom Internal - Plan View",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-35",
                "title": "2619-SEL-ZZ-XX-GA-M-1009-S3 P02 - Proposed Prefabricated Plantroom Internal - Additional Views",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-36",
                "title": "2612-SEL-ZZ-XX-CS-ME-0001-S0 T01 Tender Price Return Schedule",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/vnd.openxmlformats-officedocument.spreadsheetml.sheet"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-37",
                "title": "Blaen Y Pant ASHP - PCI V2",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            },
            {
                "id": "ocds-kuma6s-158062-document-158062-NOV561382-38",
                "title": "Tender Invite -Blaen-y-pant - ASHP",
                "datePublished": "2025-11-12T16:14:48Z",
                "dateModified": "2025-11-12T16:14:48Z",
                "format": "application/pdf"
            }
        ],
        "communication": {
            "atypicalToolUrl": "http://www.sell2wales.gov.wales/"
        },
        "additionalClassifications": [
            {
                "id": "42511110",
                "description": "Heat pumps",
                "scheme": "CPV"
            },
            {
                "id": "45315000",
                "description": "Electrical installation work of heating and other electrical building-equipment",
                "scheme": "CPV"
            },
            {
                "id": "45350000",
                "description": "Mechanical installations",
                "scheme": "CPV"
            },
            {
                "id": "51100000",
                "description": "Installation services of electrical and mechanical equipment",
                "scheme": "CPV"
            }
        ]
    },
    "noticetype": "S2W Notice - Website Invitation to Tender Notice"
}