Notice Information
Notice Title
TENDER FOR THE SUPPLY AND INSTALLATION of a Vector Network Analyser System covering frequencies up to 1.1 THz
Notice Description
The University of Birmingham invites tenders for the supply of the following equipment: THz Vector Network Analyser System The system shall be capable of measuring, to a high degree of accuracy, the full two-port scattering parameters, (both magnitude and phase) of microwave devices in the frequency range 10 MHz to 1.1 THz. The system shall include a base vector network analyser system covering 10 MHz to a suitable upper frequency (Band 1). The base VNA shall be usable on its own via a coaxial interface to cover Band 1, and usable in conjunction with a series of frequency converter units covering the waveguide bands from 140 GHz to 1.1 THz. Any gap in coverage between the top end of Band 1 and the lower frequency limit of the waveguide band converters should be kept to a minimum. The frequency converter units, supplied in pairs to permit full two-port measurements, shall extend the frequency range over which full two-port measurements can be performed, to the following specific bands, and the measurement ports shall use the rectangular waveguide standards listed for each band: o Band 2. 140 - 220 GHz, WR-5.1 o Band 3. 220 - 330 GHz, WR-3.4 o Band 4. 325 - 500GHz, WR-2.2 o Band 5. 500 - 750GHz, WR-1.5 o Band 6. 750 -1100 GHz, WR-1.0 The frequency converter heads shall meet the following requirements: o Self-contained thermal management - no additional measures are needed to cool them. o Individually characterised by the manufacturer in terms of conversion efficiency and output power. A precision calibration kit shall be provided for each of the bands 1 to 6 The interface between the base VNA and the frequency converter units will be either built in to the base VNA or provided by a separate test set controller module, and shall provide the following: o Power to drive the frequency converters. o Sufficient length in the interface cables to allow at least 10 metres separation between two test ports, for antenna and propagation measurements. o Capability to set up the base VNA to measure devices up to 1.1 THz, controlling up to four converter heads simultaneously. o Switchable between VNA test ports and converter mode. The mm-wave modules and cables do not have to be removed to use the standard VNA from test ports for use in Band 1. o Capability for the VNA to operate as a spectrum analyser in all bands up to 1.1 THz. o Capability for different converter heads to be used on test port 1 and test port 2, or for one port to use the base VNA frequency while the other uses one of the frequency converters, to enable measurements to be performed on test devices with built in frequency conversion. The base VNA shall meet the following requirements: o A user friendly user interface o Sufficient storage capacity for calibration data to avoid the need for frequently repeated calibrations by multiple users. o Coverage from 10 MHz to a high upper frequency limit (Band 1), ... Additional information: The University of Birmingham invites tenders for the supply of the following equipment: THz Vector Network Analyser System The system shall be capable of measuring, to a high degree of accuracy, the full two-port scattering parameters, (both magnitude and phase) of microwave devices in the frequency range 10 MHz to 1.1 THz. The system shall include a base vector network analyser system covering 10 MHz to a suitable upper frequency (Band 1). The base VNA shall be usable on its own via a coaxial interface to cover Band 1, and usable in conjunction with a series of frequency converter units covering the waveguide bands from 140 GHz to 1.1 THz. Any gap in coverage between the top end of Band 1 and the lower frequency limit of the waveguide band converters should be kept to a minimum. The frequency converter units, supplied in pairs to permit full two-port measurements, shall extend the frequency range over which full two-port measurements can be performed, to the following specific bands, and the measurement ports shall use the rectangular waveguide standards listed for each band: o Band 2. 140 - 220 GHz, WR-5.1 o Band 3. 220 - 330 GHz, WR-3.4 o Band 4. 325 - 500GHz, WR-2.2 o Band 5. 500 - 750GHz, WR-1.5 o Band 6. 750 -1100 GHz, WR-1.0 The frequency converter heads shall meet the following requirements: o Self-contained thermal management - no additional measures are needed to cool them. o Individually characterised by the manufacturer in terms of conversion efficiency and output power. A precision calibration kit shall be provided for each of the bands 1 to 6 The interface between the base VNA and the frequency converter units will be either built in to the base VNA or provided by a separate test set controller module, and shall provide the following: o Power to drive the frequency converters. o Sufficient length in the interface cables to allow at least 10 metres separation between two test ports, for antenna and propagation measurements. o Capability to set up the base VNA to measure devices up to 1.1 THz, controlling up to four converter heads simultaneously. o Switchable between VNA test ports and converter mode. The mm-wave modules and cables do not have to be removed to use the standard VNA from test ports for use in Band 1. o Capability for the VNA to operate as a spectrum analyser in all bands up to 1.1 THz. o Capability for different converter heads to be used on test port 1 and test port 2, or for one port to use the base VNA frequency while the other uses one of the frequency converters, to enable measurements to be performed on test devices with built in frequency conversion. The base VNA shall meet the following requirements: o A user friendly user interface o Sufficient storage capacity for calibration data to avoid the need for frequently repeated calibrations by multiple users. o Coverage from 10 MHz to a high upper frequency limit (Band 1), to limit the gap in the overall frequency coverage of the system below 140 GHz. o Sufficient output power to drive the converter heads, even when using cables for antenna and propagation measurements over a range of up to 10 m. o System Dynamic range >110dB. Is a Recurrent Procurement Type? : No
Notice Details
Publication & Lifecycle
- Open Contracting ID
- ocds-b5fd17-4826a68e-a9d3-4a4c-b0ae-ea3fb9d8bc89
- Publication Source
- Contracts Finder
- Latest Notice
- https://www.contractsfinder.service.gov.uk/Notice/76444dee-224c-4f14-a65a-2d85c85e7559
- Current Stage
- Tender
- All Stages
- Tender
Procurement Classification
- Notice Type
- Tender Notice
- Procurement Type
- Standard
- Procurement Category
- Goods
- Procurement Method
- Not Specified
- Procurement Method Details
- Tender Suitability
- SME
- Awardee Scale
- Not specified
Common Procurement Vocabulary (CPV)
- CPV Divisions
38 - Laboratory, optical and precision equipments (excl. glasses)
-
- CPV Codes
38000000 - Laboratory, optical and precision equipments (excl. glasses)
38300000 - Measuring instruments
Notice Value(s)
- Tender Value
- £1,100,000 £1M-£10M
- Lots Value
- Not specified
- Awards Value
- Not specified
- Contracts Value
- Not specified
Notice Dates
- Publication Date
- 18 Jul 20178 years ago
- Submission Deadline
- 14 Aug 2017Expired
- Future Notice Date
- Not specified
- Award Date
- Not specified
- Contract Period
- 13 Oct 2017 - 14 Nov 2022 Over 5 years
- Recurrence
- Not specified
Notice Status
- Tender Status
- Active
- Lots Status
- Not Specified
- Awards Status
- Not Specified
- Contracts Status
- Not Specified
Buyer & Supplier
Contracting Authority (Buyer)
- Main Buyer
- UNIVERSITY OF BIRMINGHAM
- Contact Name
- ADMINISTRATOR Harrison
- Contact Email
- p.e.harrison@bham.ac.uk
- Contact Phone
- 0121 414 8541
Buyer Location
- Locality
- EDGBASTON
- Postcode
- B15 2TT
- Post Town
- Birmingham
- Country
- England
-
- Major Region (ITL 1)
- TLG West Midlands (England)
- Basic Region (ITL 2)
- TLG3 West Midlands
- Small Region (ITL 3)
- TLG31 Birmingham
- Delivery Location
- Not specified
-
- Local Authority
- Birmingham
- Electoral Ward
- Edgbaston
- Westminster Constituency
- Birmingham Edgbaston
Further Information
Notice Documents
-
https://www.contractsfinder.service.gov.uk/Notice/76444dee-224c-4f14-a65a-2d85c85e7559
18th July 2017 - Opportunity notice on Contracts Finder -
https://in-tendhost.co.uk/universityofbirmingham/aspx/
Additional information on how to apply for this contract
Open Contracting Data Standard (OCDS)
View full OCDS Record for this contracting process
The Open Contracting Data Standard (OCDS) is a framework designed to increase transparency and access to public procurement data in the public sector. It is widely used by governments and organisations worldwide to report on procurement processes and contracts.
{
"tag": [
"compiled"
],
"id": "ocds-b5fd17-4826a68e-a9d3-4a4c-b0ae-ea3fb9d8bc89-2017-07-18T15:39:53+01:00",
"date": "2017-07-18T15:39:53+01:00",
"ocid": "ocds-b5fd17-4826a68e-a9d3-4a4c-b0ae-ea3fb9d8bc89",
"language": "en",
"initiationType": "tender",
"tender": {
"id": "SC5726/17",
"title": "TENDER FOR THE SUPPLY AND INSTALLATION of a Vector Network Analyser System covering frequencies up to 1.1 THz",
"description": "The University of Birmingham invites tenders for the supply of the following equipment: THz Vector Network Analyser System The system shall be capable of measuring, to a high degree of accuracy, the full two-port scattering parameters, (both magnitude and phase) of microwave devices in the frequency range 10 MHz to 1.1 THz. The system shall include a base vector network analyser system covering 10 MHz to a suitable upper frequency (Band 1). The base VNA shall be usable on its own via a coaxial interface to cover Band 1, and usable in conjunction with a series of frequency converter units covering the waveguide bands from 140 GHz to 1.1 THz. Any gap in coverage between the top end of Band 1 and the lower frequency limit of the waveguide band converters should be kept to a minimum. The frequency converter units, supplied in pairs to permit full two-port measurements, shall extend the frequency range over which full two-port measurements can be performed, to the following specific bands, and the measurement ports shall use the rectangular waveguide standards listed for each band: o Band 2. 140 - 220 GHz, WR-5.1 o Band 3. 220 - 330 GHz, WR-3.4 o Band 4. 325 - 500GHz, WR-2.2 o Band 5. 500 - 750GHz, WR-1.5 o Band 6. 750 -1100 GHz, WR-1.0 The frequency converter heads shall meet the following requirements: o Self-contained thermal management - no additional measures are needed to cool them. o Individually characterised by the manufacturer in terms of conversion efficiency and output power. A precision calibration kit shall be provided for each of the bands 1 to 6 The interface between the base VNA and the frequency converter units will be either built in to the base VNA or provided by a separate test set controller module, and shall provide the following: o Power to drive the frequency converters. o Sufficient length in the interface cables to allow at least 10 metres separation between two test ports, for antenna and propagation measurements. o Capability to set up the base VNA to measure devices up to 1.1 THz, controlling up to four converter heads simultaneously. o Switchable between VNA test ports and converter mode. The mm-wave modules and cables do not have to be removed to use the standard VNA from test ports for use in Band 1. o Capability for the VNA to operate as a spectrum analyser in all bands up to 1.1 THz. o Capability for different converter heads to be used on test port 1 and test port 2, or for one port to use the base VNA frequency while the other uses one of the frequency converters, to enable measurements to be performed on test devices with built in frequency conversion. The base VNA shall meet the following requirements: o A user friendly user interface o Sufficient storage capacity for calibration data to avoid the need for frequently repeated calibrations by multiple users. o Coverage from 10 MHz to a high upper frequency limit (Band 1), ... Additional information: The University of Birmingham invites tenders for the supply of the following equipment: THz Vector Network Analyser System The system shall be capable of measuring, to a high degree of accuracy, the full two-port scattering parameters, (both magnitude and phase) of microwave devices in the frequency range 10 MHz to 1.1 THz. The system shall include a base vector network analyser system covering 10 MHz to a suitable upper frequency (Band 1). The base VNA shall be usable on its own via a coaxial interface to cover Band 1, and usable in conjunction with a series of frequency converter units covering the waveguide bands from 140 GHz to 1.1 THz. Any gap in coverage between the top end of Band 1 and the lower frequency limit of the waveguide band converters should be kept to a minimum. The frequency converter units, supplied in pairs to permit full two-port measurements, shall extend the frequency range over which full two-port measurements can be performed, to the following specific bands, and the measurement ports shall use the rectangular waveguide standards listed for each band: o Band 2. 140 - 220 GHz, WR-5.1 o Band 3. 220 - 330 GHz, WR-3.4 o Band 4. 325 - 500GHz, WR-2.2 o Band 5. 500 - 750GHz, WR-1.5 o Band 6. 750 -1100 GHz, WR-1.0 The frequency converter heads shall meet the following requirements: o Self-contained thermal management - no additional measures are needed to cool them. o Individually characterised by the manufacturer in terms of conversion efficiency and output power. A precision calibration kit shall be provided for each of the bands 1 to 6 The interface between the base VNA and the frequency converter units will be either built in to the base VNA or provided by a separate test set controller module, and shall provide the following: o Power to drive the frequency converters. o Sufficient length in the interface cables to allow at least 10 metres separation between two test ports, for antenna and propagation measurements. o Capability to set up the base VNA to measure devices up to 1.1 THz, controlling up to four converter heads simultaneously. o Switchable between VNA test ports and converter mode. The mm-wave modules and cables do not have to be removed to use the standard VNA from test ports for use in Band 1. o Capability for the VNA to operate as a spectrum analyser in all bands up to 1.1 THz. o Capability for different converter heads to be used on test port 1 and test port 2, or for one port to use the base VNA frequency while the other uses one of the frequency converters, to enable measurements to be performed on test devices with built in frequency conversion. The base VNA shall meet the following requirements: o A user friendly user interface o Sufficient storage capacity for calibration data to avoid the need for frequently repeated calibrations by multiple users. o Coverage from 10 MHz to a high upper frequency limit (Band 1), to limit the gap in the overall frequency coverage of the system below 140 GHz. o Sufficient output power to drive the converter heads, even when using cables for antenna and propagation measurements over a range of up to 10 m. o System Dynamic range >110dB. Is a Recurrent Procurement Type? : No",
"datePublished": "2017-07-14T15:54:46+01:00",
"status": "active",
"classification": {
"scheme": "CPV",
"id": "38000000",
"description": "Laboratory, optical and precision equipments (excl. glasses)"
},
"additionalClassifications": [
{
"scheme": "CPV",
"id": "38300000",
"description": "Measuring instruments"
}
],
"items": [
{
"id": "1",
"deliveryAddresses": [
{
"postalCode": "B15 2TT"
},
{
"countryName": "British Oversea Territories"
},
{
"countryName": "Channel Islands"
},
{
"countryName": "Europe"
},
{
"countryName": "Isle of Man"
},
{
"countryName": "Rest of the World"
},
{
"countryName": "United Kingdom"
},
{
"postalCode": "B15 2TT"
},
{
"countryName": "British Oversea Territories"
},
{
"countryName": "Channel Islands"
},
{
"countryName": "Europe"
},
{
"countryName": "Isle of Man"
},
{
"countryName": "Rest of the World"
},
{
"countryName": "United Kingdom"
}
]
}
],
"minValue": {
"amount": 900000,
"currency": "GBP"
},
"value": {
"amount": 1100000,
"currency": "GBP"
},
"tenderPeriod": {
"endDate": "2017-08-14T23:59:59+01:00"
},
"contractPeriod": {
"startDate": "2017-10-14T00:00:00+01:00",
"endDate": "2022-11-14T23:59:59Z"
},
"suitability": {
"sme": true,
"vcse": false
},
"mainProcurementCategory": "goods",
"documents": [
{
"id": "1",
"documentType": "tenderNotice",
"description": "Opportunity notice on Contracts Finder",
"url": "https://www.contractsfinder.service.gov.uk/Notice/76444dee-224c-4f14-a65a-2d85c85e7559",
"datePublished": "2017-07-18T15:39:53+01:00",
"format": "text/html",
"language": "en"
},
{
"id": "2",
"documentType": "tenderNotice",
"description": "Additional information on how to apply for this contract",
"url": "https://in-tendhost.co.uk/universityofbirmingham/aspx/"
}
]
},
"parties": [
{
"id": "GB-CFS-41974",
"name": "University of Birmingham",
"identifier": {
"legalName": "University of Birmingham"
},
"address": {
"streetAddress": "Edgbaston, Edgbaston",
"locality": "Edgbaston",
"postalCode": "B15 2TT",
"countryName": "United Kingdom"
},
"contactPoint": {
"name": "ADMINISTRATOR Harrison",
"email": "p.e.harrison@bham.ac.uk",
"telephone": "0121 414 8541"
},
"roles": [
"buyer"
]
}
],
"buyer": {
"id": "GB-CFS-41974",
"name": "University of Birmingham"
}
}