Design, Manufacture, Supply, Installation and Commissioning of an Electric Furnace
Notice Description
The University require a supplier to design, manufacture, supply, install and commission an electric furnace at the Advanced Forming Research Center (AFRC)
Lot Information
Lot 1
Furnace shall comply with aeronautic, automotive & industrial standard (e.g. AMS 2750E, GE S291 & RPS 953) Note: furnace will be positioned in a workshop environment (dust & vibration) Furnace -Door opening: Width: 2800mm, Height: 2000mm, Loading height Circa 1200mm (TBC) -Useful zone: Width: 2700mm, Height: 1500mm, Length: 4000mm -Footprint: 7m long x 4m wide -Maintenance of Heating Rods through the front door -Useful zone starts at top of the fire dogs (on grid) -Noise shall not exceed 80 dba in average within an 8 hours shift -Insulation thickness should be calculated to ensure that the temperature on external wall of the furnace to be no greater than 40degC -Shall not contain asbestos or Ceramic Fibre Refractory (CFR). -Max temp: 1200degC -Operational temp: 400degC, 750degC, 850degC, 950degC, 1050degC, 1150degC -Opening time of door: shall not exceed 10s -Furnace will have vent to external atmosphere -Furnace accuracy: +/- 10degC in production (+/- 7degC at commissioning) -Furnace will have quartz viewing window on the left & right sides of the furnace for both viewing & use with optical instrumentation. Windows must be in line to allow optical path -Furnace window slots will have the option of being 'blanked out' -Heating ramp at full charge shall be 200degC/hour -Furnace shall have stairs -Furnace will have 2 heating zones one at front & one to rear -Shall be equipped with a high temperature fan to assist in heat treatment & low temperature operations -Provision for inert atmosphere (e.g N2 or Ar) Parts -Max Diameter: 600 mm -Max Length: 4000 mm -Max weight: 1000 kg -Maxi Load in the furnace: 3 parts, 3000 kg in total Instrumentation (Thermocouples) -Number of TUS thermocouples shall be minimum 14, or 9 + 5 x (number of zones - 1). The biggest number of those will be chosen. In addition to those thermocouples we should have load thermocouple according to procedure S291 -Holes in furnace walls shall be available for additional thermocouples/gas analyser probe. Two holes per zone & must be sealable when not in use -Control thermocouples shall be positioned away from the walls or gradient area in a median thermal area to avoid offset. Type R/S thermocouples to be used -Instrumentation shall be cabled following AMS2750E -Safety relay will have two thresholds above the control setup: first to alert & the second to shut down power before the control system. Type R/S thermocouples to be used -Thermocouples shall have provision to insert reference SAT thermocouple. These thermocouples to be contained within a sheath to prevent against mechanical damage. -12 additional thermocouples cables shall be installed between the recorder & a connection box on furnace. -Two 2mm thermocouples shall be installed in-between each refractory layer & casing on each wall Network architecture & Automation -HMI panel to be provided on control - Supplier shall program furnace's HMI views on the Press HMI -Must use standard communications protocol (e.g Profinet) -Must have internal data logger & connectivity means for external data collection via MQTT or OPC UA -Shall provide a record system (Network Attached Storage) & link to connect to the AFRC intranet -Shall be able to record 3 months of data & be able to transfer for archiving (every 2s). The system shall record: Soak set point, Ramp up set up per zone, Heating power -Shall be most up to date version which offers capacity for future upgrading -Shall provide Siemens PLC & HMI software (Win CC) or equivalent -At critical design review the Supplier & AFRC shall define a system of recording considering many aspects: e.g. type of data, data's importance, how data is recorded, sampling, format -Shall ensure the system incorporates comprehensive testing & diagnostic system to facilitate fault finding -Shall be able to identify different levels of fault reporting -Control of temperature within the furnace shall be done by PID via the PLC or local controller -Eurotherm controllers must be used. Please not your interest in this requirement by 22nd November 2019
Notice Details
Publication & Lifecycle
- Open Contracting ID
- ocds-r6ebe6-0000604332
- Publication Source
- Public Contracts Scotland
- Latest Notice
- https://www.publiccontractsscotland.gov.uk/search/show/search_view.aspx?ID=NOV372269
- Current Stage
- Planning
- All Stages
- Planning
Procurement Classification
- Notice Type
- OJEU - F1 - Prior Information Notice
- Procurement Type
- Standard
- Procurement Category
- Goods
- Procurement Method
- Not Specified
- Procurement Method Details
- Not specified
- Tender Suitability
- Not specified
- Awardee Scale
- Not specified
Common Procurement Vocabulary (CPV)
- CPV Divisions
42 - Industrial machinery
-
- CPV Codes
42300000 - Industrial or laboratory furnaces, incinerators and ovens
Notice Value(s)
- Tender Value
- Not specified
- Lots Value
- Not specified
- Awards Value
- Not specified
- Contracts Value
- Not specified
Notice Dates
- Publication Date
- 14 Nov 20196 years ago
- Submission Deadline
- Not specified
- Future Notice Date
- 25 Nov 2019Expired
- Award Date
- Not specified
- Contract Period
- Not specified - Not specified
- Recurrence
- Not specified
Notice Status
- Tender Status
- Planned
- Lots Status
- Planned
- Awards Status
- Not Specified
- Contracts Status
- Not Specified
Buyer & Supplier
Contracting Authority (Buyer)
- Main Buyer
- UNIVERSITY OF STRATHCLYDE
- Contact Name
- Not specified
- Contact Email
- kirstie.peffers@strath.ac.uk
- Contact Phone
- +44 1415482823
Buyer Location
- Locality
- GLASGOW
- Postcode
- G1 1QE
- Post Town
- Glasgow
- Country
- Scotland
-
- Major Region (ITL 1)
- TLM Scotland
- Basic Region (ITL 2)
- TLM3 West Central Scotland
- Small Region (ITL 3)
- TLM32 Glasgow City
- Delivery Location
- TLM82 Glasgow City
-
- Local Authority
- Glasgow City
- Electoral Ward
- Anderston/City/Yorkhill
- Westminster Constituency
- Glasgow North East
Further Information
Notice Documents
-
https://www.publiccontractsscotland.gov.uk/search/show/search_view.aspx?ID=NOV372269
Design, Manufacture, Supply, Installation and Commissioning of an Electric Furnace - The University require a supplier to design, manufacture, supply, install and commission an electric furnace at the Advanced Forming Research Center (AFRC)
Open Contracting Data Standard (OCDS)
View full OCDS Record for this contracting process
The Open Contracting Data Standard (OCDS) is a framework designed to increase transparency and access to public procurement data in the public sector. It is widely used by governments and organisations worldwide to report on procurement processes and contracts.
{
"tag": [
"compiled"
],
"id": "ocds-r6ebe6-0000604332-2019-11-14T00:00:00Z",
"date": "2019-11-14T00:00:00Z",
"ocid": "ocds-r6ebe6-0000604332",
"initiationType": "tender",
"parties": [
{
"id": "org-3",
"name": "University of Strathclyde",
"identifier": {
"legalName": "University of Strathclyde"
},
"address": {
"streetAddress": "40 George Street, Procurement Department",
"locality": "Glasgow",
"region": "UKM82",
"postalCode": "G1 1QE"
},
"contactPoint": {
"email": "kirstie.peffers@strath.ac.uk",
"telephone": "+44 1415482823",
"url": "http://"
},
"roles": [
"buyer"
],
"details": {
"classifications": [
{
"id": "Body governed by public law",
"scheme": "TED_CA_TYPE"
},
{
"id": "09",
"description": "Education",
"scheme": "COFOG"
}
],
"url": "http://www.strath.ac.uk/"
}
}
],
"buyer": {
"name": "University of Strathclyde",
"id": "org-3"
},
"planning": {
"documents": [
{
"id": "NOV372269",
"documentType": "plannedProcurementNotice",
"title": "Design, Manufacture, Supply, Installation and Commissioning of an Electric Furnace",
"description": "The University require a supplier to design, manufacture, supply, install and commission an electric furnace at the Advanced Forming Research Center (AFRC)",
"url": "https://www.publiccontractsscotland.gov.uk/search/show/search_view.aspx?ID=NOV372269",
"format": "text/html"
}
]
},
"tender": {
"id": "UOS-16198-2019",
"title": "Design, Manufacture, Supply, Installation and Commissioning of an Electric Furnace",
"description": "The University require a supplier to design, manufacture, supply, install and commission an electric furnace at the Advanced Forming Research Center (AFRC)",
"status": "planned",
"items": [
{
"id": "1",
"additionalClassifications": [
{
"id": "42300000",
"scheme": "CPV"
}
],
"deliveryAddresses": [
{
"region": "UKM82"
}
],
"relatedLot": "1"
}
],
"mainProcurementCategory": "goods",
"lots": [
{
"id": "1",
"description": "Furnace shall comply with aeronautic, automotive & industrial standard (e.g. AMS 2750E, GE S291 & RPS 953) Note: furnace will be positioned in a workshop environment (dust & vibration) Furnace -Door opening: Width: 2800mm, Height: 2000mm, Loading height Circa 1200mm (TBC) -Useful zone: Width: 2700mm, Height: 1500mm, Length: 4000mm -Footprint: 7m long x 4m wide -Maintenance of Heating Rods through the front door -Useful zone starts at top of the fire dogs (on grid) -Noise shall not exceed 80 dba in average within an 8 hours shift -Insulation thickness should be calculated to ensure that the temperature on external wall of the furnace to be no greater than 40degC -Shall not contain asbestos or Ceramic Fibre Refractory (CFR). -Max temp: 1200degC -Operational temp: 400degC, 750degC, 850degC, 950degC, 1050degC, 1150degC -Opening time of door: shall not exceed 10s -Furnace will have vent to external atmosphere -Furnace accuracy: +/- 10degC in production (+/- 7degC at commissioning) -Furnace will have quartz viewing window on the left & right sides of the furnace for both viewing & use with optical instrumentation. Windows must be in line to allow optical path -Furnace window slots will have the option of being 'blanked out' -Heating ramp at full charge shall be 200degC/hour -Furnace shall have stairs -Furnace will have 2 heating zones one at front & one to rear -Shall be equipped with a high temperature fan to assist in heat treatment & low temperature operations -Provision for inert atmosphere (e.g N2 or Ar) Parts -Max Diameter: 600 mm -Max Length: 4000 mm -Max weight: 1000 kg -Maxi Load in the furnace: 3 parts, 3000 kg in total Instrumentation (Thermocouples) -Number of TUS thermocouples shall be minimum 14, or 9 + 5 x (number of zones - 1). The biggest number of those will be chosen. In addition to those thermocouples we should have load thermocouple according to procedure S291 -Holes in furnace walls shall be available for additional thermocouples/gas analyser probe. Two holes per zone & must be sealable when not in use -Control thermocouples shall be positioned away from the walls or gradient area in a median thermal area to avoid offset. Type R/S thermocouples to be used -Instrumentation shall be cabled following AMS2750E -Safety relay will have two thresholds above the control setup: first to alert & the second to shut down power before the control system. Type R/S thermocouples to be used -Thermocouples shall have provision to insert reference SAT thermocouple. These thermocouples to be contained within a sheath to prevent against mechanical damage. -12 additional thermocouples cables shall be installed between the recorder & a connection box on furnace. -Two 2mm thermocouples shall be installed in-between each refractory layer & casing on each wall Network architecture & Automation -HMI panel to be provided on control - Supplier shall program furnace's HMI views on the Press HMI -Must use standard communications protocol (e.g Profinet) -Must have internal data logger & connectivity means for external data collection via MQTT or OPC UA -Shall provide a record system (Network Attached Storage) & link to connect to the AFRC intranet -Shall be able to record 3 months of data & be able to transfer for archiving (every 2s). The system shall record: Soak set point, Ramp up set up per zone, Heating power -Shall be most up to date version which offers capacity for future upgrading -Shall provide Siemens PLC & HMI software (Win CC) or equivalent -At critical design review the Supplier & AFRC shall define a system of recording considering many aspects: e.g. type of data, data's importance, how data is recorded, sampling, format -Shall ensure the system incorporates comprehensive testing & diagnostic system to facilitate fault finding -Shall be able to identify different levels of fault reporting -Control of temperature within the furnace shall be done by PID via the PLC or local controller -Eurotherm controllers must be used. Please not your interest in this requirement by 22nd November 2019",
"status": "planned"
}
],
"communication": {
"futureNoticeDate": "2019-11-25T00:00:00Z"
},
"coveredBy": [
"GPA"
],
"classification": {
"id": "42300000",
"scheme": "CPV"
},
"legalBasis": {
"id": "32014L0024",
"scheme": "CELEX"
}
},
"language": "EN",
"description": "NOTE: To register your interest in this notice and obtain any additional information please visit the Public Contracts Scotland Web Site at https://www.publiccontractsscotland.gov.uk/Search/Search_Switch.aspx?ID=604332. (SC Ref:604332)",
"links": [
{
"rel": "canonical",
"href": "https://api.publiccontractsscotland.gov.uk/v1/Notice?id=ocds-r6ebe6-0000604332"
}
],
"noticetype": "OJEU - F1 - Prior Information Notice"
}