Notice Information
Notice Title
Procurement of a 350-1000 nm Tunable Pulsed Laser Source
Notice Description
The National Physical Laboratory requirement is for the supply of a laser source continuously tunable over the 350-1000 nm wavelength range. The source is to be used to calibrate single-photon detectors (SPDs) in NPL's new traceable calibration facility. The source is required to be pulsed at a variable repetition rate. The pulse jitter must be short enough to allow timing jitter measurements of SPDs. The pulse width must be short enough to enable measurement of the detection profiles of gated detectors. The pulse-to-pulse energy variability must be low enough so that the intensity of individual pulses do not need to be measured, and the mean value represents a very good approximation to the energy of any individual pulse. The technologies likely to fulfil these requirements are Optical Parametric Oscillators (OPOs) with a Second Harmonic Generator (SHG) module and a stable pump laser to allow a low pulse-to-pulse amplitude uncertainty, or an Optical Parametric Amplifier (OPA) with similar SHG and stable pump laser requirement. The 350-1000 nm wavelength tuning range is required to be achieved without change of optics or re-alignment. A pulse repetition rate between 1 MHz and 100 kHz is required (10 MHz-100 kHz is desirable). The operational temperature range is at least from 15 C to 30 C.
Lot Information
Lot 1
The National Physical Laboratory requirement is for the supply of a laser source continuously tunable over the 350-1000 nm wavelength range. The source is to be used to calibrate single-photon detectors (SPDs) in NPL's new traceable calibration facility. The source is required to be pulsed at a variable repetition rate. The pulse jitter must be short enough to allow timing jitter measurements of SPDs. The pulse width must be short enough to enable measurement of the detection profiles of gated detectors. The pulse-to-pulse energy variability must be low enough so that the intensity of individual pulses do not need to be measured, and the mean value represents a very good approximation to the energy of any individual pulse. The technologies likely to fulfil these requirements are Optical Parametric Oscillators (OPOs) with a Second Harmonic Generator (SHG) module and a stable pump laser to allow a low pulse-to-pulse amplitude uncertainty, or an Optical Parametric Amplifier (OPA) with similar SHG and stable pump laser requirement. The 350-1000 nm wavelength tuning range is required to be achieved without change of optics or re-alignment. A pulse repetition rate between 1 MHz and 100 kHz is required (10 MHz-100 kHz is desirable). The operational temperature range is at least from 15 C to 30 C.
Notice Details
Publication & Lifecycle
- Open Contracting ID
- ocds-h6vhtk-041b35
- Publication Source
- Find A Tender Service
- Latest Notice
- https://www.find-tender.service.gov.uk/Notice/034239-2023
- Current Stage
- Tender
- All Stages
- Tender
Procurement Classification
- Notice Type
- Tender Notice
- Procurement Type
- Standard
- Procurement Category
- Goods
- Procurement Method
- Open
- Procurement Method Details
- Open procedure
- Tender Suitability
- Not specified
- Awardee Scale
- Not specified
Common Procurement Vocabulary (CPV)
- CPV Divisions
38 - Laboratory, optical and precision equipments (excl. glasses)
-
- CPV Codes
38000000 - Laboratory, optical and precision equipments (excl. glasses)
Notice Value(s)
- Tender Value
- £270,000 £100K-£500K
- Lots Value
- £270,000 £100K-£500K
- Awards Value
- Not specified
- Contracts Value
- Not specified
Notice Dates
- Publication Date
- 20 Nov 20232 years ago
- Submission Deadline
- 5 Jan 2024Expired
- Future Notice Date
- Not specified
- Award Date
- Not specified
- Contract Period
- Not specified - Not specified
- Recurrence
- Not specified
Notice Status
- Tender Status
- Active
- Lots Status
- Active
- Awards Status
- Not Specified
- Contracts Status
- Not Specified
Buyer & Supplier
Contracting Authority (Buyer)
- Main Buyer
- NATIONAL PHYSICAL LABORATORY
- Contact Name
- Nina Heath
- Contact Email
- nina.heath@npl.co.uk
- Contact Phone
- Not specified
Buyer Location
- Locality
- TEDDINGTON
- Postcode
- TW11 0LW
- Post Town
- Twickenham
- Country
- England
-
- Major Region (ITL 1)
- TLI London
- Basic Region (ITL 2)
- TLI7 Outer London - West and North West
- Small Region (ITL 3)
- TLI75 Hounslow and Richmond upon Thames
- Delivery Location
- Not specified
-
- Local Authority
- Richmond upon Thames
- Electoral Ward
- Teddington
- Westminster Constituency
- Twickenham
Further Information
Open Contracting Data Standard (OCDS)
View full OCDS Record for this contracting process
The Open Contracting Data Standard (OCDS) is a framework designed to increase transparency and access to public procurement data in the public sector. It is widely used by governments and organisations worldwide to report on procurement processes and contracts.
{
"tag": [
"compiled"
],
"id": "ocds-h6vhtk-041b35-2023-11-20T12:00:42Z",
"date": "2023-11-20T12:00:42Z",
"ocid": "ocds-h6vhtk-041b35",
"initiationType": "tender",
"tender": {
"id": "ocds-h6vhtk-041b35",
"legalBasis": {
"id": "32014L0024",
"scheme": "CELEX"
},
"title": "Procurement of a 350-1000 nm Tunable Pulsed Laser Source",
"status": "active",
"classification": {
"scheme": "CPV",
"id": "38000000",
"description": "Laboratory, optical and precision equipments (excl. glasses)"
},
"mainProcurementCategory": "goods",
"description": "The National Physical Laboratory requirement is for the supply of a laser source continuously tunable over the 350-1000 nm wavelength range. The source is to be used to calibrate single-photon detectors (SPDs) in NPL's new traceable calibration facility. The source is required to be pulsed at a variable repetition rate. The pulse jitter must be short enough to allow timing jitter measurements of SPDs. The pulse width must be short enough to enable measurement of the detection profiles of gated detectors. The pulse-to-pulse energy variability must be low enough so that the intensity of individual pulses do not need to be measured, and the mean value represents a very good approximation to the energy of any individual pulse. The technologies likely to fulfil these requirements are Optical Parametric Oscillators (OPOs) with a Second Harmonic Generator (SHG) module and a stable pump laser to allow a low pulse-to-pulse amplitude uncertainty, or an Optical Parametric Amplifier (OPA) with similar SHG and stable pump laser requirement. The 350-1000 nm wavelength tuning range is required to be achieved without change of optics or re-alignment. A pulse repetition rate between 1 MHz and 100 kHz is required (10 MHz-100 kHz is desirable). The operational temperature range is at least from 15 C to 30 C.",
"value": {
"amount": 270000,
"currency": "GBP"
},
"lots": [
{
"id": "1",
"description": "The National Physical Laboratory requirement is for the supply of a laser source continuously tunable over the 350-1000 nm wavelength range. The source is to be used to calibrate single-photon detectors (SPDs) in NPL's new traceable calibration facility. The source is required to be pulsed at a variable repetition rate. The pulse jitter must be short enough to allow timing jitter measurements of SPDs. The pulse width must be short enough to enable measurement of the detection profiles of gated detectors. The pulse-to-pulse energy variability must be low enough so that the intensity of individual pulses do not need to be measured, and the mean value represents a very good approximation to the energy of any individual pulse. The technologies likely to fulfil these requirements are Optical Parametric Oscillators (OPOs) with a Second Harmonic Generator (SHG) module and a stable pump laser to allow a low pulse-to-pulse amplitude uncertainty, or an Optical Parametric Amplifier (OPA) with similar SHG and stable pump laser requirement. The 350-1000 nm wavelength tuning range is required to be achieved without change of optics or re-alignment. A pulse repetition rate between 1 MHz and 100 kHz is required (10 MHz-100 kHz is desirable). The operational temperature range is at least from 15 C to 30 C.",
"value": {
"amount": 270000,
"currency": "GBP"
},
"contractPeriod": {
"endDate": "2024-08-30T23:59:59+01:00"
},
"hasRenewal": false,
"submissionTerms": {
"variantPolicy": "allowed"
},
"hasOptions": false,
"status": "active"
}
],
"items": [
{
"id": "1",
"deliveryAddresses": [
{
"region": "UK"
}
],
"deliveryLocation": {
"description": "Teddington, UK"
},
"relatedLot": "1"
}
],
"submissionMethod": [
"electronicSubmission",
"written"
],
"submissionMethodDetails": "https://lupc.bravosolution.co.uk/",
"procurementMethod": "open",
"procurementMethodDetails": "Open procedure",
"coveredBy": [
"GPA"
],
"tenderPeriod": {
"endDate": "2024-01-05T17:00:00Z"
},
"submissionTerms": {
"languages": [
"en"
]
},
"awardPeriod": {
"startDate": "2024-01-08T09:00:00Z"
},
"bidOpening": {
"date": "2024-01-08T09:00:00Z"
},
"hasRecurrence": false
},
"parties": [
{
"id": "GB-FTS-155",
"name": "National Physical Laboratory",
"identifier": {
"legalName": "National Physical Laboratory"
},
"address": {
"streetAddress": "Hampton Road",
"locality": "Teddington",
"region": "UK",
"postalCode": "TW11 0LW",
"countryName": "United Kingdom"
},
"contactPoint": {
"name": "Nina Heath",
"email": "nina.heath@npl.co.uk",
"url": "https://lupc.bravosolution.co.uk/"
},
"roles": [
"buyer"
],
"details": {
"url": "http://www.npl.co.uk",
"classifications": [
{
"scheme": "TED_CA_TYPE",
"id": "BODY_PUBLIC",
"description": "Body governed by public law"
},
{
"scheme": "COFOG",
"description": "Research"
}
]
}
},
{
"id": "GB-FTS-95510",
"name": "NPL Management",
"identifier": {
"legalName": "NPL Management"
},
"address": {
"locality": "Teddington",
"countryName": "United Kingdom"
},
"roles": [
"reviewBody"
]
}
],
"buyer": {
"id": "GB-FTS-155",
"name": "National Physical Laboratory"
},
"language": "en"
}