Notice Information
Notice Title
Particle Size Analyser & Auto-Titrator Machine
Notice Description
Natural Resources Wales Analytical Services (NRWAS) are looking purchase one Particle Size Analyser & one Auto-Titrator Machine as part of their asset replacement programme for 2024/2025. The equipment will be used for analysing a range of environmental matrices including waters (freshwater, groundwater, treated effluents) soils, sediments, passive sampler extracts and associated materials after appropriate extraction and pre-treatment. NRW are looking to purchase these machines with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability.
Lot Information
Particle Size Analyser
NRWAS are looking to purchase a Particle size analyser. The equipment will be used for analysing a range of environmental matrices such as sediments, soils, sand and associated materials. The samples will be analysed for a wide range of band sizes to comply with our environmental directives. We require the successful supplier to deliver and install the machine by 28/02/2025. We are looking to purchase this with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability. The Analyser must be able to measure the band sizes for the range1000um to <0.977 measured at 0.5 Phi intervals. The Analyser must be able to analyse for the following determinants:- - Kurtosis - Particle Diameter mean D(4,3) mm - Particle Diameter median D(v,0.5) mm - Graphic Skewness - Sorting Coefficient - Inclusive Mean - Inclusive Kurtosis The required limit of detection for the analyser is:- - Minimum fraction - 0.02 um - Minimum % volume- 0.0% - Minimum % phi - 0.0%
Auto-Titrator MachineNRWAS are looking for an auto-titrator instrument that can auto-titrate and analyse for Alkalinity and Fluoride. The equipment must have a robotic sampling system and have to ability to auto-titrate, analyse for Alkalinity and Fluoride, and produce analytical data reports. We require the successful supplier to deliver and install the machine by 28/02/2025. We are looking to purchase this with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability. The equipment will be used for analysing a range of aqueous matrices such as fresh water, treated effluent, Trade to control and acid rain water. The samples will be analysed independently for Alkalinity and Fluoride to comply with the Water Framework directives, environmental directives and pollution response. The required specification for the analysis are:- Alkalinity Instrument should have the capability to analyse for the following matrices:- - Surface River Water. - Ground Water - Treated Sewage Effluent - Trade to Control Waters - Acid rain. Required limit of detection for the instrument:- <5mg/l CaCO3 or better (Alkalinity) <-5mg/l CaCO3 or better (Grans Plot Alkalinity). Required range of analysis of the instrument :- 5mg/l - 250 mg/l (Alkalinity) -5mg/l - 250 mg/l (Grans Plot Alkalinity) N.B The instrument will need the ability to extend the ranges quoted above. Fluoride Instrument should have the capability to analyse for the following matrices:- - Surface River Water - Ground Water - Treated Sewage Effluent - Trade to Control Waters. Required limit of detection for the instrument:- <0.05 mg/l or better. Required range of analysis of the instrument :- 0.05mg/l - 1mg/l N.B The instrument will need the ability to extend the ranges quoted above.
Notice Details
Publication & Lifecycle
- Open Contracting ID
- ocds-kuma6s-143528
- Publication Source
- Sell2Wales
- Latest Notice
- https://www.sell2wales.gov.wales/search/search_switch.aspx?ID=143528
- Current Stage
- Planning
- All Stages
- Planning
Procurement Classification
- Notice Type
- OJEU - F1 - Prior Information Notice
- Procurement Type
- Standard
- Procurement Category
- Goods
- Procurement Method
- Not Specified
- Procurement Method Details
- Not specified
- Tender Suitability
- Not specified
- Awardee Scale
- Not specified
Common Procurement Vocabulary (CPV)
- CPV Divisions
38 - Laboratory, optical and precision equipments (excl. glasses)
-
- CPV Codes
38430000 - Detection and analysis apparatus
Notice Value(s)
- Tender Value
- £120 Under £100K
- Lots Value
- Not specified
- Awards Value
- Not specified
- Contracts Value
- Not specified
Notice Dates
- Publication Date
- 6 Aug 20241 years ago
- Submission Deadline
- Not specified
- Future Notice Date
- 2 Sep 2024Expired
- Award Date
- Not specified
- Contract Period
- Not specified - Not specified
- Recurrence
- Not specified
Notice Status
- Tender Status
- Planned
- Lots Status
- Planned
- Awards Status
- Not Specified
- Contracts Status
- Not Specified
Buyer & Supplier
Contracting Authority (Buyer)
- Main Buyer
- NATURAL RESOURCES WALES
- Contact Name
- Not specified
- Contact Email
- alexander.jennings@cyfoethnaturiolcymru.gov.uk
- Contact Phone
- +44 3000653000
Buyer Location
- Locality
- CARDIFF
- Postcode
- CF10 3NQ
- Post Town
- Cardiff
- Country
- Wales
-
- Major Region (ITL 1)
- TLL Wales
- Basic Region (ITL 2)
- TLL5 South East Wales
- Small Region (ITL 3)
- TLL52 Cardiff and Vale of Glamorgan
- Delivery Location
- TLL18 Swansea
-
- Local Authority
- Cardiff
- Electoral Ward
- Cathays
- Westminster Constituency
- Cardiff South and Penarth
Further Information
Notice Documents
-
https://www.sell2wales.gov.wales/search/show/search_view.aspx?ID=AUG486492
Particle Size Analyser & Auto-Titrator Machine - Natural Resources Wales Analytical Services (NRWAS) are looking purchase one Particle Size Analyser & one Auto-Titrator Machine as part of their asset replacement programme for 2024/2025. The equipment will be used for analysing a range of environmental matrices including waters (freshwater, groundwater, treated effluents) soils, sediments, passive sampler extracts and associated materials after appropriate extraction and pre-treatment. NRW are looking to purchase these machines with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability.
Open Contracting Data Standard (OCDS)
View full OCDS Record for this contracting process
The Open Contracting Data Standard (OCDS) is a framework designed to increase transparency and access to public procurement data in the public sector. It is widely used by governments and organisations worldwide to report on procurement processes and contracts.
{
"tag": [
"compiled"
],
"id": "ocds-kuma6s-143528-2024-08-06T00:00:00Z",
"date": "2024-08-06T00:00:00Z",
"ocid": "ocds-kuma6s-143528",
"initiationType": "tender",
"parties": [
{
"id": "org-10",
"name": "Natural Resources Wales",
"identifier": {
"legalName": "Natural Resources Wales"
},
"address": {
"streetAddress": "Welsh Government Offices, Cathays Park, King Edward VII Avenue",
"locality": "Cardiff",
"region": "UKL",
"postalCode": "CF10 3NQ"
},
"contactPoint": {
"email": "alexander.jennings@cyfoethnaturiolcymru.gov.uk",
"telephone": "+44 3000653000"
},
"roles": [
"buyer"
],
"details": {
"classifications": [
{
"id": "Body governed by public law",
"scheme": "TED_CA_TYPE"
},
{
"id": "05",
"description": "Environmental protection",
"scheme": "COFOG"
}
],
"url": "http://naturalresourceswales.gov.uk"
}
}
],
"buyer": {
"name": "Natural Resources Wales",
"id": "org-10"
},
"planning": {
"documents": [
{
"id": "AUG486492",
"documentType": "plannedProcurementNotice",
"title": "Particle Size Analyser & Auto-Titrator Machine",
"description": "Natural Resources Wales Analytical Services (NRWAS) are looking purchase one Particle Size Analyser & one Auto-Titrator Machine as part of their asset replacement programme for 2024/2025. The equipment will be used for analysing a range of environmental matrices including waters (freshwater, groundwater, treated effluents) soils, sediments, passive sampler extracts and associated materials after appropriate extraction and pre-treatment. NRW are looking to purchase these machines with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability.",
"url": "https://www.sell2wales.gov.wales/search/show/search_view.aspx?ID=AUG486492",
"format": "text/html"
}
]
},
"tender": {
"id": "ocds-kuma6s-143528-tender-143528",
"title": "Particle Size Analyser & Auto-Titrator Machine",
"description": "Natural Resources Wales Analytical Services (NRWAS) are looking purchase one Particle Size Analyser & one Auto-Titrator Machine as part of their asset replacement programme for 2024/2025. The equipment will be used for analysing a range of environmental matrices including waters (freshwater, groundwater, treated effluents) soils, sediments, passive sampler extracts and associated materials after appropriate extraction and pre-treatment. NRW are looking to purchase these machines with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability.",
"status": "planned",
"items": [
{
"id": "1",
"additionalClassifications": [
{
"id": "38430000",
"scheme": "CPV"
}
],
"deliveryAddresses": [
{
"region": "UKL18"
}
],
"relatedLot": "1"
},
{
"id": "2",
"additionalClassifications": [
{
"id": "38430000",
"scheme": "CPV"
}
],
"deliveryAddresses": [
{
"region": "UKL18"
}
],
"relatedLot": "2"
}
],
"value": {
"amount": 120,
"currency": "GBP"
},
"mainProcurementCategory": "goods",
"lots": [
{
"id": "1",
"title": "Particle Size Analyser",
"description": "NRWAS are looking to purchase a Particle size analyser. The equipment will be used for analysing a range of environmental matrices such as sediments, soils, sand and associated materials. The samples will be analysed for a wide range of band sizes to comply with our environmental directives. We require the successful supplier to deliver and install the machine by 28/02/2025. We are looking to purchase this with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability. The Analyser must be able to measure the band sizes for the range1000um to <0.977 measured at 0.5 Phi intervals. The Analyser must be able to analyse for the following determinants:- - Kurtosis - Particle Diameter mean D(4,3) mm - Particle Diameter median D(v,0.5) mm - Graphic Skewness - Sorting Coefficient - Inclusive Mean - Inclusive Kurtosis The required limit of detection for the analyser is:- - Minimum fraction - 0.02 um - Minimum % volume- 0.0% - Minimum % phi - 0.0%",
"status": "planned"
},
{
"id": "2",
"title": "Auto-Titrator Machine",
"description": "NRWAS are looking for an auto-titrator instrument that can auto-titrate and analyse for Alkalinity and Fluoride. The equipment must have a robotic sampling system and have to ability to auto-titrate, analyse for Alkalinity and Fluoride, and produce analytical data reports. We require the successful supplier to deliver and install the machine by 28/02/2025. We are looking to purchase this with a 1 year warranty, and a 4 year service and maintenance contract to follow. If possible, we will be looking to secure a further 5 year service and maintenance contract with the successful supplier subject to supplier availability. The equipment will be used for analysing a range of aqueous matrices such as fresh water, treated effluent, Trade to control and acid rain water. The samples will be analysed independently for Alkalinity and Fluoride to comply with the Water Framework directives, environmental directives and pollution response. The required specification for the analysis are:- Alkalinity Instrument should have the capability to analyse for the following matrices:- - Surface River Water. - Ground Water - Treated Sewage Effluent - Trade to Control Waters - Acid rain. Required limit of detection for the instrument:- <5mg/l CaCO3 or better (Alkalinity) <-5mg/l CaCO3 or better (Grans Plot Alkalinity). Required range of analysis of the instrument :- 5mg/l - 250 mg/l (Alkalinity) -5mg/l - 250 mg/l (Grans Plot Alkalinity) N.B The instrument will need the ability to extend the ranges quoted above. Fluoride Instrument should have the capability to analyse for the following matrices:- - Surface River Water - Ground Water - Treated Sewage Effluent - Trade to Control Waters. Required limit of detection for the instrument:- <0.05 mg/l or better. Required range of analysis of the instrument :- 0.05mg/l - 1mg/l N.B The instrument will need the ability to extend the ranges quoted above.",
"status": "planned"
}
],
"communication": {
"futureNoticeDate": "2024-09-02T00:00:00Z"
},
"coveredBy": [
"GPA"
],
"classification": {
"id": "38430000",
"scheme": "CPV"
},
"legalBasis": {
"id": "32014L0024",
"scheme": "CELEX"
}
},
"language": "EN",
"description": "If you have an interest in providing a bid for one or both of these instruments, feel free to email Alex Jennings (alexander.jennings@cyfoethnaturiolcymru.gov.uk) and inform us know which lot/s you're interested in and the estimated lead time for the delivery and installation of the machine/s. NOTE: To register your interest in this notice and obtain any additional information please visit the Sell2Wales Web Site at http://www.sell2wales.gov.wales/Search/Search_Switch.aspx?ID=143528. (WA Ref:143528)",
"links": [
{
"rel": "canonical",
"href": "https://api.sell2wales.gov.wales/v1?lang=cy/Notice?id=ocds-kuma6s-143528"
}
],
"noticetype": "OJEU - F1 - Prior Information Notice"
}